Pinout and Connectivity
Power Input
Pin | Function |
---|---|
1 | 18-60V Input |
2 | Ground |
Notes:
- The power input is galvanically isolated.
CAN Bus
Pin | Function |
---|---|
4 | CAN Bus High |
5 | CAN Bus Low |
6 | Ground |
The CAN Bus connections support CAN FD (ISO 11898-1) with a data rate up to 5Mbps.
Notes:
- Each CAN Bus connection is galvanically isolated.
- Each CAN Bus connection has a permanent 120Ω termination.
- All other pins are not connected.
Modbus
Pin | Function |
---|---|
1 | Ground |
2 | Ground |
3 | RS485 A |
4 | Ground |
5 | Ground |
6 | RS485 B |
7 | Ground |
8 | Ground |
Notes:
- Each Modbus connection is galvanically isolated.
I/O
Pin | Function |
---|---|
1 | Relay 1+ |
2 | Relay 1- |
3 | Relay 2+ |
4 | Relay 2- |
5 | Digital Out 1 |
6 | Isolated Ground |
7 | Digital Out 2 |
8 | Isolated Ground |
9 | Digital In 1 |
10 | Isolated Ground |
11 | Digital In 2 |
12 | Isolated Ground |
Notes:
- Each relay is fused at 3A with a non-resettable fuse.
- The maximum voltage for each relay is 30VDC and 250VAC.
- Each digital output is fused with a 1A non-resettable fuse.
- The maximum voltage for each digital input is 30VDC.